CWE/103/2017 当前世界环境 0973-4929 2320-8031 Enviro Research Publishers CWE--8-00 Determination of water quality of different areas of Kaithal,Haryana 2 , Zublliant Pharmaceuticals, Noida, India. 2008-07-05 10.12944 / CWE.3。1.17 Volume 3 Volume 3 123-126 Abstract

Ground water which were taken from the various places of in and around Kaithal town were analyzed and the analysis reports that the water quality parameters like pH, EC, Cl-,TDS ,Ca2+, Mg2+ and Hardness lies within the maximum permissible limit prescribed by WHO and ICMR. Except few parameters like DO, few samples were reported with lower DO than the permissible level, but this value does not have any impact for the water to use for drinking purpose.

关键字 Total Hardness Conductivity EDTA Titrimetric Method