• google scholor
  • Views: 6197

  • PDF Downloads: 277

Air Microbial Contamination at the Holy Mosque, Makkah, Saudi Arabia

A.A Abdel Hameed1*and T. Habeeballah1

1Department of Environmental and Health Research, The custodian of the Two Holy Mosques, Institute for Hajj and Umrah, Umm-Al Qura University, 21955 Saudi Arabia

DOI:http://dx.doi.org/10.12944/CWE.8.2.03

Airborne microbial contamination was collected from the main directions of the holly mosque (Al-Haram mosque), Makkah city, by using the gravitational method. Bacteria, fungi and actinomycete concentrations ranged between 1470– 21800 CFU/m3; 44 - 572 CFU/m3, and 0.0 - 264 CFU/m3, respectively at all directions. Bacterial concentrations significantly differed between directions, and Gram positive bacteria constituted ~ 90-100% of the total bacterial isolates. Gammaproteobacteriawerethe common Gram negative bacteria, andAspergilluswas the predominant fungal genera. Mesophilic bacteria negatively related (P< 0.05) with relative humidity. Human activities had more effective influence on the microbial concentrations than the meteorological factors.

Air; Biocontamination; Directions; Biodiversity; The Holly Mosque; Makkah

Copy the following to cite this article:

Abdel Hameed A. A, Habeeballah T. Air Microbial Contamination at the Holly Mosque, Makkah, Saudi Arabia. Curr World Environ 2013;8(2) DOI:http://dx.doi.org/10.12944/CWE.8.2.03

Copy the following to cite this URL:

Abdel Hameed A. A, Habeeballah T. Air Microbial Contamination at the Holly Mosque, Makkah, Saudi Arabia. Curr World Environ 2013;8(2). Available from://www.a-i-l-s-a.com/?p=4916


Download article (pdf)
Citation Manager
Publish History


Article Publishing History

Received: 2013-07-15
Accepted: 2013-08-20

Introduction

Atmospheric particles of biological origin are diverse group of microorganisms and their execrations. Airborne microorganisms originate from many sources: animal, human, and vegetation. The number and composition of airborne microorganisms have increased in the urban and rural areas.1The presence of microorganisms depends on seasonality, geographical conditions, meteorological factors, type of sources,2,3,4and air pollution.5Airborne microorganisms may contribute ~ 20%, 22% and 10% of the total particulate matters in the remote continental, populated-continental, and remote maritime environments, respectively.6The concentrations and composition of airborne microorganisms undergoes daily, weekly and seasonally changes.7

Millions of people arrive to the Holy City, Makkah city, particularly in the Ramadan month,the fasting month, every year. Microbial contamination represents a dangerous risk factor in many human activities areas,8as airborne microorganisms cause allergy, infections, and toxicity.9,10Some studies have been carried out on microbial contamination in the atmosphere of Saudi Arabia cities: such as Riyadh,11胡富夫,12Makkah,13and Taief.14However few studies have been performed on the airborne microorganisms in the area near and around the holly mosque. The results showed that microbial concentrations differed depending on methodology and sampling location.15,16

Until now no complementary studies have dealt with airborne microbial community at the main directions of the holly mosque that may be differed in their human activities and topographical features. The evaluation of microbial contamination, in places at risk, is considered a basic step toward prevention and control. The present study aims to gain more insight into the variability of airborne bacteria, fungi, and actinomycetes at the main directions of the holly mosque, in order to determine its microbial air quality and give site specific information.

Materials and Methods

Site Description

The Holy City, Makkah, is located at an altitude of 277 m, 21°29'N 39°45'E, and ~ 80 km inland from the Red Sea, with a population of ~2,000, 000.17The area around the holly mosque comprises the old city; which is characterized by heavy traffic, parking, hotels, and hospitals with no predominant plant cover. Four sampling sites were selected to carry out the present study. Air samples were collected at the main directions (North, South, West and East) of the holly mosque (Fig. 1), in order to represent various geographical features and human activities. A brief summary of the general human activities and environmental characteristics at each direction are shown in Table 1.
Figure 1. A diagram of the holly mosque showing sampling points Figure 1: A diagram of the holly
mosque showing sampling points

Click here to View figure
Table 1. A brief description of the environmental features around the holly mosque Table 1: A brief description of the environmental
features around the holly mosque

Click here to View table

During every sampling event, temperature and relative humidity were measured using a portable Psychrometer (Extech -model 42270, China), adjusted to record data at every 10 min intervals. Temperatures ranged between 27– 35oC with mean values of 30.3oC, 29.6oC, 31.4oC and 30.8oC at the North, South, East, and West, respectively. Relative humidity ranged between 32–63% with mean values of 38.7%, 43%, 34% and 42% at the corresponding directions, respectively. Wind speed records were obtained from The Presidency of Meteorology and Environment, Makkah. The wind speed ranged between 0.5 to 1.5 m/s, with north-east was the prevailing wind direction.

Sampling Strategy

A total of 16 samples were collected between 19thto 27thdays of Ramadan (7-15, August, 2012). Two consecutive samples were collected every sampling event. Air samples were collected at ~1 - 3 m height above the ground level, between 19.00 PM and 24.00 AM, the night time. This time was chosen because it is the time of the overcrowding in the holly mosque during the Ramadan month. The gravitational method was used to collect airborne culturable microorganisms. The Petri plates, in triplicate, containing trypticase soya agar, czapek's dox agar, and starch casein agar (Hi-Media Laboratories, Mumbai, India) media were used to collect bacteria, fungi and actinomycetes, respectively. The sampling time varied within 10-20-min. The exposed plates were incubated for 5– 7 days at 28oC for fungi; 48 hrs at 22 and 37oC for psychophilic, and mesophilic bacteria; respectively, and 10 days at 25oC for actinomycetes.

The resultant colonies were counted and converted into colony forming unit per cubic meter of air (CFU/ m3) using Omeliansky formula18:

N=5a x 104(bt)-1

Where:N= colony forming unit per cubic meter of air (CFU/m3) a= number of colonies per Petri dish, b=dish square centimeter, t= exposure time (min).

All the grown fungal colonies, and five to ten bacterial colonies which appear in more than 5% of trypticase soya agar were purified and identified to the genus level.Aspergilluswas identified to the species level. The bacterial isolates were identified on the basis of Gram stain, oxidase, and catalase tests.19Fungal isolates were identified using macroscopic and microscopic features.20-23

Statistical Analysis

Data was analyzed using the non parametric statics. The kruskal Wallis test was used to compare microbial contamination at the different directions (p<0.05), followed by post hoc test (Student t-test). The assumption for this test is that the samples from different groups are randomly independent. Spearman's rank correlation test (rs) was used to determine the relationships between microbial concentrations and meteorological factors.

Results

The range and mean concentrations of airborne culturable microorganisms at the main directions of the holly mosque are shown in Table 2. The bacterial concentrations ranged between 1470- 21800 CFU/m3, with mesophilic bacterial concentrations exceeded psychophilic concentrations. The highest bacterial concentration was found at the north direction, and the lowest at the East. Fungal concentrations ranged between 44 - 572 CFU/m3, with the highest concentrations were found at the North and West directions. Airborne actinomycete concentrations were found in the range of 0-264 CFU/m3(表2),嗜中温psychophilic细菌concentrations significantly differed between the all directions (P<0.05), however fungi and actinomycete concentrations did not show any significant differences.
Table 2. The range and mean concentrations of airborne microorganisms at the main directions of the holly mosque Table 2: The range and mean concentrations of
airborne microorganisms at the main directions
of the holly mosque

Click here to View table

A total of 502 bacterial isolates belonging to 11 genera were identified (Fig. 2). Gram positive and negative bacteria constituted 90-100% and 2.4 - 9.4%, respectively of the total isolates. Staphylococci (4.2-26%), andBacillus(5.5- 30.9%) were the dominant Gram positive bacteria.Streptococciand spore-formers were only detected at the north and south directions, respectively. Gammaproteobacteria (Pseudomonas) constituted 8.75% of the total isolates at the south direction (Fig. 2). A total of 112 fungal isolates belonging to 19 genera were identified (Fig. 3).Aspergillusrepresented byAspergillus fumigatus,Aspergillus nigerandAspergillus flavus.Aspergillus niger(14.27 %- 46.9%) andFusarium(6.90% - 13.62%) were the common fungal isolates. The highest fungal diversity was found at the south direction, among whichEpicoccum,Mucor,Trichophyton,Chaetomium,Cladosporium,Alternaria,Emericellawere detected.
Figure 2. Identification of airborne bacterial genera at the different directions Figure 2: Identification of airborne bacterial
genera at the different directions

Click here to View figure
Figure 3. Identification of airborne fungal genera at the different directions Figure 3: Identification of airborne
fungal genera at the different directions

Click here to View figure

Table 3 shows the agreement ratios between the identified microbial isolates between directions. The agreement ratio is used to compare the identified microorganisms among sampling sites, as it reflects the number of shared genera at the different sites in relation to the total number of genera.24High agreement ratios were found between bacterial genera at the all directions. The agreement ratios for fungi were relatively lower than bacteria, the highest ratio (0.65) was found between the North and East directions.
Table 3. Similarity triangle depicting agreement ratios among microbial isolates at the different directions Table 3: Similarity triangle depicting agreement ratios
among microbial isolates at the different directions

Click here to View table

No clear relationships were found between the meteorological parameters and airborne microorganisms. The relationships differ according to type of bio-contaminant and direction. However, relative humidity was considered the main factor affecting survivability of mesophilic bacteria (r=- 0.4 - - 0.8). Actinomycetes negatively related with temperature, however fungi negatively and positively related with relative humidity, and temperature, respectively. Wind speed show weak negative and positive relationships with microbial concentrations.

Discussion

空气微生物污染是重要的issue in the crowded centers and cities, as air serves as a transmission vehicle for pathogens that have linked with adverse health effects ranging from infectious diseases to allergies and cancer.25Airborne microorganisms affect individuals who are at risk, immune-compromised, elders and children, particularly in overcrowded areas, however, human responses depend on type of microorganism, and individual’s immune system.26Various sampling methods are used to collect airborne microorganisms including, impaction, impingement, filtration and gravity deposition.27Passive and active sampling methods are based on different principles. The passive samplers yielded data with the lowest standard deviation in comparison with the active samplers.28In the present study, the gravitational method was used because it is a simple, cheap, and many places can be checked at the same time. The gravitational method is a non-quantitative method,29as it is affected by the size and shape of the particles, and motion of the surrounding atmosphere.30Omeliansky formula is not a universal conversion formula; however it is used to allow comparing our results with other results that were obtained by using the active samplers.

Airborne microbial concentrations ranging from 4,500–10,000 CFU/m3被认为是t吗he upper limit for ubiquitous bacterial aerosols,31and concentration < 100 cfu/m3may be unhealthy to immunosuppressed people.32In the present study bacterial concentrations exceeded 104CFU/m3at the North and South directions. However, fungal concentrations did not exceed the allowable guideline limit value of 500 CFU/m3.33Actinomycetes exceeded 100 CFU/m3, strongly contaminated air, and 10– 100 CFU/m3, moderately contaminated air at some directions as suggested by Polish Standards.34

Airborne bacterial concentrations exceed 1x104CFU/m3over land,35as bacteria may be suspended as individual cells or attached to other particles such as soil and leaf.36Airborne fungal concentrations generally ranged from 100-103CFU/m3,37and averaged ~104CFU/m3in the urban air.1Airborne actinomycetes averaged 102CFU/m3in the Cairo city centre,38as actinomycetes are highly dependent on the amount of dust in the air.39

Airborne microbial contamination is affected by multiple variables. These variables continuously changed, such as anthropogenic influence, human activity, topography, micro-environmental conditions, type of sources, and seasonality.1In the present study traffic flow disturbed dust particles at the north direction that might be the reason for increasing of microbial concentration. The lowest microbial concentration was found at the East direction. This is attributed to the absence of direct human disturbances, and good natural ventilation. Generally microbial concentrations in the urban environment are influenced by human activities,40and their composition varies in different cities.41在目前的研究有不清楚些小的ns found between airborne microorganisms and meteorological factors. This is attributed to the influence of irregular disturbances and human activities, which may have more influence on microbial concentrations than meteorological factors near the holly mosque. The lack of significant relationships does not mean that meteorological factors have no effects on microbial survivability, because in un-standardized conditions severe microbial variations are expected.

In the present study Gram positive bacteria were common. This could be explained on the bases of their cell wall structure and continuous sources. The low frequent detection of Gram negative bacteria is attributed to their sensitivity to the air environment,41and the initial shock due to desiccation after aerosolization.42Firmicutes, Proteobacteria and Actinobacteria are common bacterial types in the urban environment, where Gammaproteobacteria and Betaproteobacteria have been regularly identified.1Mouli et al.,43found airborne Gram positive bacteria in the range of 60% - 90% of the total bacterial population, in Tirupati, India; howeverBacillusconstituted 47.62% andAcinetobacteria14.27% in the atmosphere of El Taief, Saudi Arabia.44 Bacillus,MicrococcusandStaphylococcidiffered from place to place depending on the micro-environment.45In the present study the frequent detection ofPseudomonasspecies at the south direction is of a particular interest as the spray humidifiers, and water reservoirs are suspected to be their sources.

Airborne fungi is likely to be similar in most parts of the world, however the dominating genera may differ from area to another, depending on the density of plant cover, geographical location, and human activity.46In the present study,Alternaria,PenicilliumandCladosporiumwere found in low counts becausePenicillium and Cladosporiumfavor low temperature conditions, and sensitive to solar radiation.47 Alternariaproliferates in the presence of suitable humidity, temperature, and vegetation debris,48these conditions are not available in the Saudi Arabia, as low humidity, high temperature and no permanent plant cover are the main characters of Makkah city.Fusariumcan grow in water pipes, fresh water and humidifiers,49this confirms the presence ofFusariumin the air around the holly mosque. In the present study phyloplane and water indicators fungi50were detected in lower counts than soil fungi.

Actinomycetes may induce respiratory symptoms,10streptomycetes have been implicated in many diseases and several species stimulate lung macrophage reactions that lead to inflammation of the lung9. Aspergillus, Eurotium, Penicillium and Trichoderma species have been known as a cause of allergenic alveolitis.51Aspergillus flavus and Aspergillus fumigatus cause aspergillosis.52Gram negative bacteria are an important source of endotoxins, which are the main pulmonary immunotoxicants.53Gram-positive bacteria should also be regarded as potential immunotoxicants.54Bacillus species have been found to be associated with allergic alveolitis.55The potential for extensive transmission of airborne infectious agents is present in large public settings; however the duration of exposure may be short. At the holly mosque, particularly in the Ramadan month, the duration of exposure to microbial contamination may be extended to be >10 hour/ day and the probability of infection may be present. Therefore a program for surveillance, prevention and control of airborne microbial contamination should be established at the holly mosque.

Conclusion

Airborne microbial concentrations not significantly varied between the main directions of the holly mosque. Airborne bacteria were the main microbial contaminants. The biodiversity of bacterial and fungal genera were higher at the south direction; however the north had the largest microbial concentrations. The anthropogenic activities are the main variables controlling air bio-contamination around the holly mosque. The spray humidifiers are suspected to be the main emission source ofPseudomonasbacteria. People may be exposed to infectious agents at the holly mosque; therefore the microbial contents should be included in the air quality standards and reports.

References
  1. Després V.R., Huffman J. A., Burrows S .M, Hoose C, Safatov A. S., Buryak G., Fröhlich-Nowoisky J., Elbert W., Andreae M. O., Pöschl U., Jaenicke R.,Tellus B, 64, 15598 (2012).
  2. De Linares C., Belmonte J., Canela M., Díaz de la Guardia C., Alba-Sanchez F., Sabariego S., Alonso-Pérez S., Agricultural and Forest Meteorology, 150, 1491 (2010).
  3. Womack A.M., Bohannan B.J.M., Green J.L.,Phil. Trans. R. Soc. B,365 (1558), 3645 (2010).
  4. Brodie E.L., DeSantis T.Z., Parker J.P.M., Zubietta I.X., Piceno Y.M., Andersen G.L., PNAS, 104, 299 (2007).
  5. Abdel Hameed A.A., Khoder M.I., Ibrahim Y.H., Saeed Y., Osman M.E., Ghanem S., Sci. Total Environ., 414, 696 (2012).
  6. Matthais-Maser S., Obolkin V., Khodzer T., Jaenicke R., Atmospheric Environment, 34, 3805 (2000).
  7. Kaarkainen P., Meklin T., Rintala H., Hyvärinen A., Kakkäinen, Vepŝalainen A, Hirvonen M-R, Nevalainen A, Clean-Soil, Air, Water, 36 (7), 556 (2008).
  8. Pasquarella, C., Pitzurra, O., Savino A., J. Hosp Infect, 46, 241 (2000).
  9. Lacey J., Airborne actinomycete spores as respiratory allergens, In: Schaal K.P. and Pulverer G. (eds), Actinomycetes. Zbl. Bakteriol. Mikrobiol. Hyg. 1 Abteil. Suppl. Gustav Fischer Verlag, Stuttgart, pp. 243 (1981).
  10. Rylander R. and Jacobs R.R.,Int J Occup Environ Health1997;3, S1–48 (1997).
  11. Al-Falih A.M. A., Pakistan J. Biol. Sciences, 4 (6), 736 (2001).
  12. Al-Sheikh H., Saudi J. Biol. Sci., 15, 237 (2008).
  13. Al-Falih A. and Qahtani Y., Saudi Biological Society , 19thAnnual Meeting, (1998).
  14. Abdel Hafez S. I. I., Mycopathologia, 88, 39, (1984).
  15. Abed K.F., J of King Saud University, Science Section, 14, 2, (2000).
  16. Mashat B.,Study on airborne microbial content indoor and outdoor of Al Haram mosque during Ramadan 1428H, Technical Report, Umm-Al Qura University, Saudi Arabia, (2009), (in Arabic).
  17. CDSI, Central Department of Statistics and Information, Saudi Arabia, (2010).
  18. Abdel Hameed A.A. and Abdel Mawla H., Polish J of Environ. Studies, 21, 1539, (2012).
  19. El-Gendy S.,Biological air pollution at different types of waste handling facilities. Ph.D. Thesis, Faculty of Science, Mansoura Univ., Egypt (2012).
  20. Ellis M.,Dematiaceous hyphomycetes, The Western Press Ltd, London and Reading Commonwealth Mycological Institute Kew, Surrey, UK, p. 608 (1971).
  21. Barnett H.L.,Illustrated Genera of Imperfect Fungi, Minneapolis, Minnesota: Burgess Publishing Company (1972).
  22. Al-Musallam A.,Revision of the black aspergillus species. Ph.D. Thesis, Utrechi, Netherlands, University of Utrecht (1980).
  23. Barnett H. and Hunter B.,Illustrated genera of imperfect fungi. 4thed. St. Paul, MN: The American Phytopathological Society, APS; p. 218 (1999).
  24. Macher J.M.,Data analysis, Chapter 13. In: Bioaerosols: Assessment and Control, ACGIH Kemper Meadow Drive, Cincinnati, Ohio 45240-1634 (1999).
  25. Peccia J., Hospodsky D., Bibby K., Atmos. Environ., 45, 1896 (2011).
  26. ACGIH, American Conference of Governmental Industrial Hygienists, Bioaerosols: Assessment and Control, ACGIH, Cincinnati, Ohio (1999).
  27. Griffin D.W., Clin. Microbiol. Rev., 20, 459 (2007).
  28. Pitzurra M., Pasquarella C., Pitzurra O., Savino A., Ann Ig, 8, 349 (1996).
  29. Buttner M.P., Willeke K., Grinspun, S.A Buttner M.P., Willeke K., Grinspun, S.A., Sampling and analysis of airborne microorganisms. In: Hurst C.J., Knudsen G.R., McInerney M.J., Stetzenbach L.D., Walter M.V. (Eds.),Manual of Environmental Microbiology, American Society for Microbiology, Washington, 629 (1997).
  30. Nevalainen A.K., Willeke F., Lienhaber J., Pastsuszka A., Burge H., Henningston E.,采样器采样:原理、技术和美联社plications. New York: van Nostrand Reinhold, pp. 471 (1993).
  31. Nevalainen, A., Bacterial aerosols in indoor air. Ph.D. thesis. University of Kuopio, Kuopio, Finland,pp 58, 66, 73 (1989).
  32. ACGIH, American Conference of Governmental Industrial Hygienists.Guidelines for the assessment about aerosols in the indoor environment, Cincinnati, Ohio (1989).
  33. WHO,Indoor air quality: biological contaminants: Copenhagen: WHO, Regional Office for Europe (1990).
  34. Polish Standards, PN-89/Z-04111/03 [Polska Norma PN-89/Z- 04111/03].Protection of air cleanness. Microbiological study. Enumeration of microscopic fungi in atmospheric air (emission) during samples collection by impact and sedimentation methods(1989), (in Polish).
  35. Bauer H.; Kasper-Giebl A.; Löflund M.; Giebl H.; Hitzenberger R.; Zibuschka F.; Puxbaum H., Atmos. Res, 64, 109 ( 2002).
  36. Lighthart B., FEMSW Microbiol. Ecol.,23, 263 (1997).
  37. Pady S.M., Gregory P.H., Transact. Brit.. Mycol. Soc., 46, 609 (1963).
  38. Abdel Hameed A.A., Studies on microbial indicators in ambient air in greater Cairo, Ph.D. thesis Faculty of Science, Mansoura University, Egypt (1996).
  39. Lloyd A.B.,J. Gen. Microbiol., 57, 35 (1969).
  40. Fang Z., Ouyang Z., Zheng H., Wang X., Hu L., Microbial Ecol., 54, 487 (2007).
  41. Karra S. and Katsivela E., Water Research, 41, 1355 (2007).
  42. Cox C. and Wathes C.,Bioaerosols Handbook, CRC Press LLC, Lewis Publishers (1995).
  43. Mouli P.C., Mohan S.V., Reddy S.J. Mouli P.C., Mohan S.V., Reddy S.J., Appl. Ecol. Environ. Research, 3, 139 (2005).
  44. Mahdy H.M., El-Sehrawi M., Water, Air and Soil Pollution, 98, 317 (1996).
  45. Burkowska A., Kalwasińska A., Walczak M., Pol. J. Environ. Stud, 21, 307 (2012).
  46. Abdul Wahid A., Moustafa A., Moustafa A., Aerobiologia, 12, 249 (1996).
  47. Topbas M., Tosun L., Cangamze Kaklikkaya N., Aydin F., Town Turk J. Med. Sci., 36, 31 (2006).
  48. Sen B. and Asan A., Environ. Monit. Assess, 15, 209 (2009).
  49. Morey P.R., Microbiological investigations of indoor environments: interpreting sampling data-selected case studies, In: Flannigan B, Samson R.A., Miller J.D.:Microorganisms in home and indoor work environments (diversity, health impacts, investigation and control, 2ndEd, CRC press, Taylor and Francis Group (2011).
  50. Horner W., Worthan A., Morey P., Appl. Environ. Microbiol., 70, 6394 (2004).
  51. Lacey J. and Dutkiewicz J., J. Aerosol Sci., 25, 1371 (1994).
  52. Campbell C.K., Forms of aspergillosis. In the genusAspergillus, Edited by KA Powell, A Renwick and JF Poberdy, New York: Plenum, pp 313, (1994).
  53. Dutkiewicz, J., Pneumonologia i Alergologia Polska, 60 (Suppl 2), 14 (1992).
  54. Burrell, R., Annals of Agr and Environ. Med., 2(1), 11 (1995).
  55. Johnson C. L,. Bernstein I. L,. Gallagher J. S., Bonventre P. F., Brooks S. M., Am. Rev. Resp. Dis., 122, 339 (1980).