Environmental Implications of pH in a Pervious Concrete Pavement on Highway BR-319, Amazonas, Brazil

Evailton Arantes de Oliveira1*, Maria do P. S. Lamêgo Oliveira1, Arlene M. Lamêgo da S. Campos3, Murilo Ferreira dos Santos2, Jessica Adriane Afonso Souza2, Maria João Correia de Simas Guerreiro4and Maria Alzira Pimenta Dinis4

Corresponding author Email:35986@ufp.edu.pt

DOI:http://dx.doi.org/10.12944/CWE.13.2.03

This research studies the carbonation phenomenon of cement due to the reaction of its components with water. In this chemical reaction occurs the formation of calcium carbonate and the absorption of CO2 in the atmosphere, which contributes to the reduction of the Greenhouse Effect. However, carbonation also causes pathologies such as efflorescence, staining and corrosion of steel in concrete. This research shows the results of experiments with specimens of concrete permeable, made with cement and big aggregates (calcareous stone) in the ratio of 1: 4.4 (cement: stone) and a factor of 0.3 for water / cement. The specimens were kept in contact with water containing different amounts of CO2 - distilled, ionized alkaline, carbonated, and tap water. After the experiments were carried out, an increase in pH, a mean compressive strength of 12.3 MPa and a permeability rate of 1.28 l / h was observed. The results show that the permeable concrete did not present any pathologies resulting from the carbonation during the period of the research, which recommended the same for use in road pavements.

Brazil; Carbonation; Highway Pavement; Pervious Concrete; Resistance to Compression

Copy the following to cite this article:

Oliveira E. A. D, Santos M. F. D , Sou za J. A. A , Campos A. M. L. D. S, Oliveira M. D. P. S. L, Guerreiro M.J.C.D.S, Dinis M.A.P. Environmental Implications of pH in a Pervious Concrete Pavement on Highway BR-319, Amazonas, Brazil.Curr World Environ 2018;13(2). DOI:http://dx.doi.org/10.12944/CWE.13.2.03

Copy the following to cite this URL:

Oliveira E. A. D, Santos M. F. D , Sou za J. A. A , Campos A. M. L. D. S, Oliveira M. D. P. S. L, Guerreiro M.J.C.D.S, Dinis M.A.P. Environmental Implications of pH in a Pervious Concrete Pavement on Highway BR-319, Amazonas, Brazil. Curr World Environ 2018;13(2). Available from://www.a-i-l-s-a.com/article/1088/


Download article (pdf)
Citation Manager
Publish History


Article Publishing History

Received: 2018-05-25
Accepted: 2018-08-23
Reviewed by: OrcidOrcidDr. Avinash Prabhu (India)
Second Review by: OrcidOrcidDr. Simona Azzali (Singapore)
Final Approval by: Dr. Umesh Chandra Kulshrestha

Introduction

Concrete has cement as a binder, therefore, it is subject to two phenomena: calcination and carbonation.1The cement manufacturing process consumes energy and generates carbon dioxide (CO2) due to calcination, whereas carbonation of cement, a natural process of calcium carbonate formation in the concrete hydration process, uptakes CO2 from the environment, an interesting environmental factor that may contribute to reduction of this greenhouse gas.2,3In fact, cement carbonation in construction may reduce CO2 in the environment, with a positive impact on the greenhouse effect. Nonetheless, carbonation may contribute to concrete pathology by steel corrosion in reinforced concrete4. The importance of investigating the environmental implications of pH variation in drainage water from porous concrete is related to cement carbonation.5Upon the hydrolysis reaction, an increase in the solubility of calcium carbonate, incorporates carbon dioxide, leading to an acidity in the water, once the system is in equilibrium. Sustainability requirements in today’s constructions compel to investigate materials whose waste can be recycled.3This research work focused on the effects of carbonation in porous concrete, which may include recycling of concrete by using it as an aggregate contributing to pavements6construction sustainability. The main objective of this study was to investigate evidence of carbonation in specimens of pervious concrete, under laboratory and field conditions of pressure and temperature, and to verify the integrity of specimens of pervious concrete subject to different types of water: distilled, alkaline ionized water, carbonated water and tap water.

Materials and Methods

This study was developed in Manaus, in the Amazon region in Brazil, and involved laboratory and field experiments.

Pervious Concrete Specimens

Pervious concrete specimens were formed based on the Brazilian standard NBR 57387, that defines the procedures to mold and cure concrete specimens. Based on studies of traits, preparation methods, standard quality control as well as permeability concrete optimization methods8, ten cylindrical specimens of pervious concrete were formed, with a cement to coarse aggregate 1:4.4 ratio and a water/cement factor of 0.3 to compression (Table 1).

Table 1: Pervious Concrete Specimens Characteristics

Material

Ratio

cement : coarse aggregate ratio

1:4.4

water / cement factor

0.3

aggregate (4.8 a 9.5 mm) (kg/m3)

1660

cement (kg/m3)

374


The specimens were molded into cylindrical shapes of 10 cm in diameter by 20 cm. The compaction consisted on applying 15 strokes with a shank, by layer of equal thickness. Vibration, curing and demolding were performed according to the guidelines of Brazilian standard NBR 5738, considering that the characteristics of pervious concrete differ from common concrete.9

The infiltration rate was evaluated using distilled (DIS), ionized (ION), tap (TAP) and carbonated (CAR) water (Figure 1). Water adsorption was calculated by weight difference after the samples were left to air dry for 24 hours and after water (DIS, ION, TAP, and CAR) had infiltrated through the specimen.


Figure1: measurement of a) pH and temperature; b) infiltration rate

在碳化和calcinatio pH值变化n10: the chemical reaction in cement manufacture, where calcium carbonate dissociates into carbon dioxide and calcium oxide, requires a lot of thermal energy and releases its carbon dioxide into the atmosphere. Carbonation (equations 1 and 2) is the inverse reaction of calcination (Equation 3), where carbon dioxide is slowly absorbed by the concrete during its lifetime (Equations 1 to 3).



The hydrolysis reaction consumes CO32-(aq) and increases the solubility of calcium carbonate. Therefore, the incorporation of carbon dioxide creates an acidity in water, which can be detected by pH measurement, after the equilibrium displayed in Equation 3:



Thus, the indication of pH change can be used as a method to verify if carbonation in the specimens of pervious concrete is occuring.13Evaluation of pH difference was performed in each sample (Figure 1), with a time interval of 24 hours, in the following order: DIS, ION, TAP, CAR. The samples were left to air dry for 24 hours, after which weighing with a precision scale of ± 0.2 g would take place.

Results

Pervious concrete specimen average infiltration rate, pH e temperature before/after percolation are presented in Table 2.

Table 2: Experimental Data

Sample

Weight

Infiltration

rate

pH before/after

percolation

temperature before/after percolation (ºC)

(g)

(mm/hr)

DIS

ION

TAP

CAR

DIS

ION

TAP

CAR

1

3,354.30

1.14

7.4/

7.1

9.6/

8.7

8.5/

5.1

5.4/

3.2

22.7/

21.9

23.5/21.9

27.0/

24.2

24.3/

21.8

2

3,236.90

1.27

8.2/

7.1

9.8/

8.7

8.6/

5.1

5.1/

3.2

22.9/

22.1

23.2/

21.5

25.9/

22.8

24.3/

21.3

3

3,308.20

1.31

7.6/

7.1

9.6/

8.7

7.8/

5.1

4.6/

3.2

22.5/

21.3

22.9/21.2

27.1/

23.4

23.5/

21.1

4

3,304.80

1.23

7.6/

7.1

9.6/

8.7

8.5/

5.1

4.7/

3.2

22.5/

21.6

22.4/

20.9

27.0/

22.9

23.1/

21.1

5

3,285.80

1.27

7.5/

7.1

9.5/

8.7

8.3/

5.1

4.6/

3.2

22.3/21.1

22.3/

21.1

25.3/

22.3

22.7/

20.7

6

3,148.50

1.22

8.0/

7.1

9.6/

8.7

8.8/

5.1

4.6/

3.2

22.2/

21.8

22.6/

21.5

25.3/

22.3

22.7/

20.6

7

3,257.00

1.55

7.7/

7.1

9.4/

8.7

8.3/

5.1

4.5/

3.2

21.8/

20.6

22.6/

22.3

26.1/

23.4

22.5/

21.4

8

3,405.90

1.26

7.4/

7.1

9.3/

8.7

8.2/

5.1

4.0/

3.2

21.3/

20.6

22.7/

22.7

25.8/

23.6

22.6/

22.0

9

3,164.30

1.31

8.2/

7.1

9.2/

8.7

9.0/

5.1

4.3/

3.2

21.5/

21.2

21.1/

20.0

25.3/23.9

22.4/

22.0

10

3,269.90

1.26

8.8/

7.1

9.4/

8.7

8.5/

5.1

4.3/

3.2

21.6/

21.5

21.1/19.9

25.0/

24.3

22.8/

21.7


Discussion

Infiltration Rate


As shown in Figure 3, the infiltration rate showed little variation between specimens for the same water type. The highest rates (smaller filtration time) were always under distilled water, suggesting that minerals may affect infiltration rates. Infiltration rate is within the expected parameters.15

Figure 2: Time of filtration of the different types of water in the specimens of pervious concrete
Click here to view figure


Nonetheless, the Kruskal-Wallis ANOVA test, using filtration time of tap water as a grouping variable, demonstrates that samples are homogeneous, with ap-value=0.429 for CAR,p-value of 1.000 for ION, andp-value of 0.317 for DIS. Table 3 shows the descriptive statistics of filtration times for the four water types.

Table 3. Filtration Time Descriptive Statistics

Water type

Tap

Carbonated

Ionized

Distilled

mean

1.5

1.1

1.4

1.1

standard deviation

0.361

0.079

0.070

0.038

Variance

0.130

0.006

0.005

0.001


Water Adsorption

Water adsorption in the specimens varied from 1.2% to 1.6%, with distilled and tap water showing less adsorption than carbonated or ionized water (Table 3), based on the non-parametric Kruskal-Wallis test with seven degrees of freedom, using weight difference of water as a grouping variable. Results showed ap-value= 0.339 for CAR,p-value= 0.357 for ION, andp-value=0.339 for DIS, implying that samples were homogeneous.

Table 4. Adsorption on Pervious Concrete Specimens

Types of water

吸附(%)

pervious concrete specimens

Distilled water (DIS)

1.2

Ionized water (ION)

1.6

Tap water (TAP)

1.2

Carbonated water (CAR)

1.5


Figure 2 shows difference in weight before and after the infiltration process, suggesting that water adsorption is higher under ionized water, followed by carbonated water, distilled and tap water, suggesting that water with higher carbon concentration tends to adsorb more to concrete. Differences between samples are attributed to differences in porosity due to concrete molding.

Figure 3: Weight difference pervious concrete specimens, before and after water infiltration
Click here to View figure


如图4所示,所有的水samples filtered through the pervious concrete specimens changed their pH. Tap water and carbonated water showed higher pH differences, whereas ionized and distilled water showed smaller differences. These results suggest that pervious concrete adsorbs CO2from carbonated water, changing its pH.

Figure 4: pH difference of the pervious concrete specimens, before and after filtration of the different types of water
Click here to View figure


The Kruskal-Wallis test, using the difference data of pH of tap water as a grouping variable, resulted in ap-valueof0.860 for CAR,p-value of 0.471 for ION, andp-value of 0.481 for DIS, implying that samples are homogeneous (p> 0.05).

Descriptive statistics (Table 5), the natural water presented the mean with the greatest difference of values between pH before and pH after filtration, while ionized water and distilled water showed the lowest mean with the difference between pH before and after pH filtration. It is assumed that natural water needs less filtration time to undergo greater pH changes, i.e., water with gas, ionized water and distilled water need to remain contained in the pores of the pervious concrete to undergo greater pH changes.

Table 5: pH Descriptive Statistics

Water type

Tap

Carbonated

Ionized

Distilled

Mean

3.4

1.4

0.8

0.7

Standard deviation

0.331

0.401

0.176

0.321

Variance

0.109

0.161

0.031

0.103



Having pervious concrete large and interconnected pores in addition to the typical micropores of cement paste11, this structure allows ambient air and water to more easily reach the inner spaces. When water flows through pervious concrete, pH of water changes due to the calcium hydroxide and calcium carbonate in the cement slurry12, with lower pH values, indicating more calcium carbonate or a greater amount of carbonation. The pH change indicates that water encountered calcium hydroxide, with a pH increase. Nonetheless, in this experiment there was no time for formation of calcium carbonate, therefore, it was not possible to detect the carbonation by the reduction of pH in the samples, in these laboratory experiments.

Conclusions

The results obtained in the laboratory and in the field showed that:

low absorption of tap and distilled water by pervious concrete specimens, is an advantage if it is intended to be used as road paving material, increasing stability under rainfall conditions;

filtration time, associated to infiltration rate, showed little variation under different water types, suggesting that pervious concrete is use is not constrained by carbon concentration in water;

pH increase in water samples after infiltration through pervious concrete specimens, in the laboratory and in the field experiments suggest contact of rainwater with the calcium hydroxide in the cement paste, but carbonation and CO2sequestration could not be detected probably because there was not enough time for calcium carbonate formation.

These preliminary studies suggest that carbonation was not detected by the methodology used, so it would be interesting to perform other tests, such as X-ray diffraction to identify the chemical components in the samples being tested that serve as evidence of carbonation in the cement.

Acknowledgments

The authors are grateful to University Fernando Pessoa (Porto - Portugal) for the guidance provided, Uninorte University - Laureat International for permission to use the Chemistry Laboratory and Concrete Laboratory of the Coordination of the Civil Engineering Course, Manaus, Amazon, Brazil, and the National Department of Infrastructure and Transport – DNIT, Brazil, for the support of the scientific research taking place. This research had no external funding sources.

References

  1. Haselbach l., Thomle J. An Alternative Mechanism for Accelerated Carbon Sequestration in Concrete.Sustainable Cities and Society, 2014;12:25.
    CrossRef
  2. Thomle J., Haselbach L. The Declining pH of Waters Exfiltrated Through Pervious Concrete.Sustainable Cities and Society, 2011;12:25.
  3. Pade C., Guimarães M. The CO2Uptake of Concrete in 100 Years Perspective.Cement and Concrete Research, 2007;37:1348-1356.Hõltz F. C. Use of Permeable Concrete in Urban Drainage: Technical Feasibility and Environmental Impact Analysis. Master's Dissertation UFRS, School of Engineering, Porto Alegre, Brazil, 2011.
  4. Ho L. S., Nakarai K., Ogwa Y., Sasaki T., Morioka M. Effect of Internal Water Content on Carbonation Progress in Cement-treated Sand and Effect of Carbonation on Compressive Strength.Cement and Concrete Composites,2018; 85:9.
    CrossRef
  5. Branch J. L., Epps R., Kosson D. S. The Impact of Carbonation on Bulk and ITZ Porosity in Microconcrete Materials with Fly ash Replacement.Advances in Materials Science & Engineering, 2018; 103:170.
  6. El-Hassan H., Kianmehr P. Sustainability Assessment and Physical Characterization of Pervious Concrete Pavement made with GGBS.MATEC Web of Conferences, 2017; 120:07001.
    CrossRef
  7. Associação Brasileira de Normas Técnicas. NBR 5738: Molding and Cure of Cylindrical and Prismatic Concrete Samples. (In Portuguese), Rio de Janeiro, 1994.
  8. Rangelov M., Nassiri S., Chen Z., Russell M., Uhlmeyer J. Quality Evaluation Tests for Pervious Concrete Pavements Placement.International Journal of Pavement Research and Technology, 2017;10(3):245.
    CrossRef
  9. Batezini R., Balbo J.T. Study on the Hydraulic Conductivity by Constant and Falling head Methods for Pervious Concrete. IBRACON Structure and Materials Journal, 2015, 8(3), 248-259.
  10. Arrigoni A., Pelosato R., Melià P., Ruggieri G., Sabbadini S., Dotelli G. Life Cycle Assessment of Natural Building Materials: The Role of Carbonation, Mixture Components and Transport in the Environmental Impacts of Hempcrete blocks.Journal of Cleaner Production, 2017;149:1051.
    CrossRef
  11. Georget F., Prévost J. H., Huet B. Impact of the Microstructure Model on Coupled Simulation of Drying and Accelerated Carbonation.Cement and Concrete Research, 2018;104:1.
    CrossRef
  12. Hunnicutt W., Struble L., Mondal P. Effect of Synthesis Procedure on Carbonation of Calcium-silicate-hydrate.Journal of the American Ceramic Society, 2017;100: 3736.
    CrossRef