• 谷歌scholor
  • 观点:3463

  • PDF下载:433

沸水温度对PTI社区饮用水生物膜形成的影响

电子艺界Fadairo1和M.I.奥蒂-道格拉斯1

1工业安全和环境技术部,石油培训学院埃富伦,PMB 20埃富伦,尼日利亚三角洲州

DOI:http://dx.doi.org/10.12944/CWE.10.1.10

本研究考察了煮沸温度和相关理化参数对石油培训学院饮用水的影响,以及在其输送系统中形成生物膜的可能性。本研究共使用了25个饮用水样本。考察环境参数为pH、电导率、总溶解固体(TDS)、总悬浮固体(TSS)、溶解氧(DO)1), /做5盐度、电阻率、总大肠菌群(作为分布系统中可能存在生物膜的指标)和生物膜。除女旅舍在定性生物膜试验中表现为中等染色外,加沸和减沸饮用水样品中大肠菌群总感染率均<1。减沸水样品pH值在5.04±0.47 ~ 6.82±0.48之间;总悬浮物为0.09±0.05 ~ 0.17±0.02,总溶解固体为4.07±0.73 ~ 5.58±0.70,电导率为8.02±0.90 ~ 11.54±1.67,溶解氧为1.97±0.26 ~ 3.12±0.135电阻率范围为1.91±0.32至2.72±0.29,电阻率范围为7.79±0.13至10.88±0.18。加沸水和过滤后的样品pH值范围为6.02±0.26 ~ 6.95±0.26;电导率7.21±0.10 ~ 9.88±0.67;DO范围为1.01±0.14 ~ 2.08±0.35,DO 5范围为1.02±0.02 ~ 2.01±0.38,TSS和TDS分别为0.02±0.001、3.74±0.62 ~ 0.03±0.002和4.95±0.42,电阻率范围为1.02±0.11 ~ 1.98±0.16。所分析的所有参数值均在世卫组织对饮用水的限值范围内,但对FSH -沸水样品进行的定性生物膜试验给出了0.1%结晶紫染色的中度染色,pH值低于世卫组织可接受的限值。这项研究倡导对饮用水进行煮沸和过滤,不论其来源如何,以加强研究所社区内水传播疾病的预防和管理。

沸腾的温度;生物膜的形成;物理化学变化;PTI社区

复制下面引用这篇文章:

王晓明,王晓明,王晓明,等。沸水温度对Pti社区饮用水生物膜形成的影响。当代世界环境2015;10(1)DOI:http://dx.doi.org/10.12944/CWE.10.1.10

复制以下内容引用此URL:

王晓明,王晓明,王晓明,等。沸水温度对Pti社区饮用水生物膜形成的影响。生态学报,2015;10(1)。可以从://www.a-i-l-s-a.com/?p=9021


下载文章(pdf)
引用管理器
发布历史


文章发表历史

收到: 2015-02-10
接受: 2015-04-14

介绍

最近观测到的高点大肠杆菌该研究所宿舍住宿居民的血液样本中的水平引起了极大关注。大肠菌群传统上被用作大肠杆菌饮用水源污染。虽然大肠菌群的检测可能不会造成严重影响,但它的存在表明存在其他引起疾病的生物体,或者可能在管道系统内形成一层细菌(生物膜)以及其他原因。人们关注饮用水生物膜的主要原因是管网中大肠菌群的生长。Pontius(1995)报道了1993年、1994年和1995年美国因配管网中大肠菌群生长而违反饮用水标准的事件。研究还表明,由于在饮用水成品中反复检测到大肠菌群,美国有近2000个系统存在严重的不合规性。最近的研究检查了来自90多个供水系统的数据,以确定导致饮用水中大肠菌群细菌发生的因素, 1996;沃尔克, 1996)。这些研究表明,饮用水中大肠菌群的出现与以下因素有关:过滤、温度、消毒剂类型、剩余可吸收有机碳水平、腐蚀控制和管道材料选择(Lechevallier)et al。, 1996;沃尔克et al。, 1996)。生物膜还可能导致消毒剂残留的损失、细菌水平的增加、溶解氧的减少、饮用水的味道和气味、铁或硫酸盐还原细菌造成的红水或黑水问题、微生物影响的腐蚀、水力粗糙度和材料寿命的缩短(characklis和marshal, 1990年)。生物膜的这些作用原则上取决于界面的物理化学条件,如pH值、氧浓度、氧化还原电位和离子强度等。有报道称,生物膜的存在会引起这些参数浓度的变化(www.efcweb.org)。研究表明,有冷水的系统会增加大肠菌群的数量。pH值对净化能力的影响已被广泛研究,在大多数情况下,据报道pH值在细菌死亡中起作用(Hirn)。, 1980;Tejordoet al。, 1992)。饮用水管网中的生物膜是造成水质问题的主要原因。报告称,大多数人类持续感染,包括口腔、肺部、阴道和异物相关感染,都是基于生物膜的(Watnick和Kolter, 2000;Tumbarello, 1996;Saify., 2013)也引起了我们对这项研究的关注。生物膜的一个重要特征是,单个微生物通过微生物排泄的聚合物质结合在一起,形成粘附基质(细胞内粘附多糖),将生物膜结合在一起,使其能够附着在表面上,并可以作为包封物保护形成生物膜的菌落(Ghellai), 2014)。这种保护性包封被认为在最近经历的一些抗生素耐药感染中发挥了作用(Lewis, 2001年)。

因此,本项目以大肠菌群浓度为指标,研究煮沸温度对生活饮用水中可能形成的生物膜的影响。这项研究的结果将用于向社区内的水消费者宣传煮沸和过滤在预防常见水传播疾病中的重要性。

材料与方法

样品的收集和制备

本研究共使用了25个有代表性的样本。从女性宿舍、男性宿舍、高级员工宿舍和初级员工宿舍的5个水龙头中随机抽取5个样品,并从位于Effurun PTI路的不同商店购买了5个150cl的Eva水。样本是在凌晨从随机选择的20个水龙头中收集的。将样品分为A、B、C、D、e四组。A组样品为5瓶Eva瓶装水,作为对照。B组为贵族女学生宿舍(FSH)的饮用水。C组的样本取自男学生宿舍的5个水龙头,而D组和E组的样本分别取自高级教职员宿舍和初级教职员宿舍。立即对样品进行理化参数分析、生物膜及大肠菌群检测。部分负沸水样品在不处理氯和其他微生物耗氧抑制剂的情况下,孵育5天后测定溶解氧。剩余样品分类为A1B1C1,D1和E1经煮沸、冷却、过滤、相同理化参数分析、定性生物膜和定量大肠菌群试验。煮沸和冷却后的样品也孵育5天,进行5天溶氧试验。

生物膜检测管法

Christensen描述的简单生物膜检测方法1982年,美国国会通过了一项略作修改的法案。将怀疑含有试验生物的样品接种于含有1%葡萄糖的10 mL胰酶大豆肉汤中., 2006)在试管中。37ºC孵育24 h。孵育后,将试管滗出,用200µl磷酸盐缓冲盐水(pH 7.2)洗涤4次,并干燥。然后用结晶紫(0.1%w/v)染色et al。, 2003;Mathur, 2006)。多余的污渍用去离子水洗净。管子在倒置位置干燥。根据对照样品的结果对试管法进行评分。当一层明显的膜排列在管壁和管底时,生物膜的形成被认为是阳性的。在本研究中,形成的生物膜的数量被评分为1分(弱/无),2分(中等),3分(高/强)。实验进行了三次,重复了三次(克里斯滕森)et al .,1982)。

大肠菌群的测定

采用Fernandez概述的多管技术测定大肠菌群浓度, 1992年。样品中大肠菌群的检测培养基分别为假定阶段、确认阶段和完成阶段的月桂基胰蛋白酶肉汤、亮绿色乳糖胆汁肉汤和伊红亚甲基蓝。样品在35±0.5℃下孵育0C作用24小时±2小时,48小时±3小时,24小时±2小时,分别检测大肠菌群测定的三个阶段的气体形成情况。大肠杆菌鉴定报告为CFU/100ml。

物理化学性质的测定

本研究选取的理化参数是按照饮用水可接受水质评价的多屏障政策来选择的,建议将总大肠菌群的监测与其他指标相结合。水样的pH值在煮沸前和研究结束时在塑料瓶底部切割前测定。水样的pH值使用数字型号Jenway 3520 pH计在26±2下测定oC (aoac, 2000)。电导率、电阻率、盐度和TDS采用氯化钾校准多7兆托莱多电导率仪测定。在20℃孵育前,使用Jenway 9500溶解氧计,根据改进的起皱剂和膜探针法(由起皱剂于1888年首次提出,并由美国环保局在其2007年SOP中修订)分析溶解氧(DO)oC为第5天DO分析。根据ASTMD 5907-10对水中可过滤物质和不可过滤物质进行重量分析,由Adeogun概述et al。, 2011年。

统计分析

使用INSTAT®统计软件对数据进行分析。结果表3.1、3.2和3.3给出了未煮沸和加煮沸饮用水的理化参数和大肠菌群数量。对于正沸水,25个样品均不含生物膜和大肠菌群;而对于负沸水,0.99%的样品经大肠菌群细菌测试后,均不含生物膜和大肠菌群。负沸水和正沸水中生物膜存在的定性分析结果见表3.1。
表3.1:PTI中负沸水和正沸水的定性生物膜试验 表3.1:PTI中负沸水和正沸水的定性生物膜试验
点击这里查看表格

负沸点卵泡刺激素样品在生物膜测试的五管中有一管显示中度染色。在生物膜检测前煮沸同一样品,0.1%结晶紫未染色(表3.1)。表3.2表示从研究所及其周边5个地点提取的减沸水中所调查的大肠菌群与理化参数的关系
表3.2:PTI低沸点饮用水样品大肠菌群数量与理化参数的关系。 表3.2:大肠菌群之间的关系
的理化参数
在PTI中减去煮沸的饮用水样品。

点击这里查看表格

表3.3给出了大肠菌群数量与5个不同地点的饮用水样本与PTI群落的关系
表3.3:PTI群落内煮沸饮用水大肠菌群数量与理化参数的关系 表3.3:大肠菌群之间的关系
的计数和理化参数
在PTI社区煮沸饮用水

点击这里查看表格

讨论

本研究考察了沸点温度对饮用水生物膜形成和水质的影响。pH值被用作衡量水是否适合某一特定用途的指标(Adeogun), 2011;Jonnalagadda and Mhere, 2001)。通过对表3.2的检查,可以发现pH值一直很低。这可能是由于尼日利亚尼日尔三角洲地区的石油勘探和开采活动产生酸雨后,水的酸性。这与(Efe和Mogborukor, 2012)的工作一致,他们证明了原油精炼过程中气体燃烧产生的酸雨对尼日尔三角洲水质的影响。水样经煮沸处理后pH值升高,但无统计学意义(P>0.05)。溶解氧浓度高,生产力高,污染少。本研究中,女宿舍的负沸水样本(表3.2)的溶解氧浓度相对于相应的正沸水样本(表3.3)的溶解氧浓度下降,可能是污染的迹象。但二者差异不显著(P>0.05),均在WHO饮用水可接受限值内。水电导率的测量是连续监测净水系统性能趋势的一种典型方法。电导率是衡量水通过电流的能力。 Pure water is said to be a low conductor of electric current. The observed high concentration of electrical conductivity of minus-boiling potable water sample from the female hostel and all water sample analyzed relative to the control, Eva bottled water could also be an indication of contamination. Although, values obtained fall within WHO acceptable limit for potable water (2004). Conductivity is used as an estimation of total dissolved solids in water. The high levels of electrical conductivity observed in all samples of minus-boiling potable water relative to the control, Eva bottled water, could be due to the high levels of total dissolved solids of the same groups. Increase water temperature has been reported to reduce dissolve oxygen (DO) content of water. The low value obtained for DO of plus-boiling water relative to its minus-boiling water values could be due to boiling. Albeit, dissolved oxygen is not usually considered as a parameter for potable water analysis but in this study we investigated the DO value for day 1 and 5 to enable us ascertain that our suspicion regarding coliform bacteria presence especially in the FSH sample that showed a mild positive result in biofilm screening was incorrect. The dissolved oxygen values for boiled water, day1 and day 5 were almost equal. This could be that the minute biological agents in the minus boiling potable water sample was destroyed by the boiling process. Boiling also reduced the values obtained for total dissolved solids. This could imply that certain non filterable solute in the sample may have been precipitated out at boiling temperature. The low values recorded for total suspended solid in the plus-boiling potable water samples groups may possibly be because of the filteration carried out on the samples after boiling. In this study, salinity values were the same for minus boiling and plus boiling water samples irrespective of the source while resistivity value was reduced significantly (P<0.05) in plus boiling groups relative to the minus-boiling potable water samples. Except for pH values and the qualitative biofilm test result, values obtained in this study fall within the WHO standard for drinking water (2004).

结论

根据我们的研究结果,本研究提倡在研究所内煮沸饮用水,以预防和管理水传播疾病。对这项研究结果的另一种解释可能意味着研究所饮用水源可能没有得到充分处理,因为大肠菌群可以在储存系统生物膜中增殖,而在女性宿舍的低沸水样本中观察到适度的生物膜存在。一个问题是机会致病菌是否会扩散。

Aknowledgement

作者感谢三角洲州埃夫伦石油培训学院石油分析实验室的所有工作人员在本研究过程中提供了必要的实验室协助。

参考文献
  1. Adeogun, a.o., Chukwuka, a.v.和Ibor, O.R.(2011)。屠宰场和锯木厂污水对阿贝奥库塔奥根河上游水质的影响。美国环境科学杂志,7(6): 525-530。
  2. (2000)。官方分析方法th编辑:官方分析化学家协会:美国弗吉尼亚州阿灵顿。
  3. Borucki, MK, Peppin, JD。, White, D., Loge, FJ.。(2003)。单核增生李斯特菌生物膜形成的变异。环绕。Microbiol, 69:7336 - 7342。
  4. Characklis, w.g.和Marshall, K.C.(1990)。微生物污染与微生物生物污染控制,In: W. G. Characklis和K. C. Marshall(主编):Biofilm, John Wiley and Sons inc ., New York, 523-634。
  5. Christensen GD, Simpson WA, Bisno AL, Beachey EH。(1982)。黏液产生菌株的粘附葡萄球菌epidermidis使表面光滑。感染Immun,37:318 - 326。
  6. 柯林斯,CH,莱恩,PM,格兰奇,JM。(2004)。微生物的方法。阿诺德出版社,伦敦,英国456页
  7. 唐兰RM。(2001)。生物膜和器械相关感染。突发传染病;7(2): 277 - 81。,
  8. Efe, S.I和Mogborukor, J.O.(2012)。尼日尔三角洲地区酸雨对水资源质量和危机的启示。AFRREV STECH1(1); 17-46。
  9. 格莱,L.,哈桑,H.,克劳什,N.;,卡迪尔,A,艾萨维,N。,Nas, F and Zingg, W. (2014). Detection of Biofilm formation of a collection of fifty strains of Staphylococcus aureus isolated in Algeria, journal of Bacteriology Research, vol. 6(1), pp. 1-6
  10. Hirn, J., Viljamaa, H .和Raevouri, M.(1980)。物理化学、浮游植物和季节因素对北部咸水粪便指示菌的影响。Res, 4, 279-285
  11. Jonnalagadda, S。(2001)。津巴布韦东部高地奥济河的水质。水物35:2371 - 2376。
  12. M. W. Lechavallier(1990)。饮用水中大肠菌群的再生研究进展美国水务协会杂志中文信息学报,32(2):74-86。
  13. 莱切瓦利尔,m.w.,韦尔奇,n.n。J和史密斯,D.B.(1996)。饮用水中胆状菌再生相关因素的全面研究。应用环境微生物学;62:2201。
  14. 李维斯,K.(2001)。生物膜抗性之谜。抗菌剂化学试剂;45:999 - 1007。
  15. Mathur, T., Singhal, S., Khan, S., Upadhyay, DJ, Fatima, T., Rattan, A.(2006)。葡萄球菌临床分离株生物膜形成的检测:三种不同筛选方法的评价。中华医学杂志,2014(1):25-29。
  16. 《水和废物化学分析方法》(1979)U.S. EPA 600/ 4€79 €020,方法405.1。
  17. Pontius, F.(1995)。SDWA顾问或CD.丹佛,科罗拉多州;美国自来水厂。
  18. Saify, H., Patidar, r.k., Khare, M., Sahare, k.n.和Singh, V.万古霉素和环丙沙星耐药金黄色葡萄球菌临床分离株生物膜发育能力的差异。传染病;1:8。
  19. 水和废水检验的标准方法。(1992)。apha - awwa - WEF, 18™版,方法5210。
  20. Tejedor, C, Fernandez,A。,和Chordi, A.(1992)。水、空气和土壤污染。Kluver学术出版社,荷兰印刷,63年;317 - 320。
  21. Tumbarello, M., Tacconelli, E., Lucia, M., Cauda, R .和Ortona, L.(1996)。金黄色葡萄球菌肺炎与人类免疫缺陷病毒感染相关的预测因素。和地中海,90: 531 - 7
  22. 美国环境保护署(1991)。指导手册,用于完成公共水系统使用表面的过滤和消毒要求。水源。美国环境保护局,华盛顿特区。
  23. 环境保护署(2010)。国家一级饮用水法规:对总大肠菌群法规的修订提出的规则。美国环境保护署,华盛顿特区(EPA-HQ-OW。2008 - 0878)。
  24. Volk, C。,Welch, N and Lechevallier, M. W. (1996). Survey of Assimilable Organic Carbon and Coliform Regrowth in the American Water System. Voorhees, N.J.; American water works service company, inc.
  25. 沃特尼克,P和科尔特,R.(2000)。生物膜微生物之城”。细菌学杂志,vol.182 no . 10;页2675 - 2679。
  26. 谁。(2004)。3 .饮用水质量标准理查德·道金斯版。期。建议。世界卫生组织,瑞士日内瓦。
  27. www.efcweb.org/microbial。